Analyseurs
BM 200 2nd Generation
- Throughput - 240 tests/hour (without ISE), 360 tests/hour
(with ISE Na, K, Cl) - Optional build-in PC
- Special anti-noise and high ergonomic design
- Methodology - end-point, two-point and kinetic,
colorimetric and turbidimetric measurement - QC - Westgard, Multi rules and L-J rules
- Conection to LIS - HL7 Protocol
- Barcode reader for sample and reagents
- Water consumption - max 2,5 l/hour
- Optional ISE module
- Optional Touch screen
- 40 sample positions - no special positions for calibrators,
controls and stat samples-possibility of use as many controls
and calibrators as needed - Up to 5 virtual sample trays
- 40 reagent positions, possible input 2 lots of the same reagent
- or share reagent between tests
- Possible reagents recognition by barcode reader
- Refrigerated sample/reagent compartment 4-10°C
- Real time reagent volume monitoring
- 81 reaction cuvettes with special ultraviolet transmitting material
- Hot air thermostat
- Full-sealed matrix spectrometric system
- 8 wavelengths from 340-670 nm, 800 nm optional
- Halogen lamp with 2000 working hours life
- Sample and reagent probe with liquid level detection
and 3-D collision protection. - Maintenance free dilutor
- Minimum reaction volume - 150 μl
- Contamination free sample probe and stirrer
BM 300
- Throughput - 300 tests/hour (without ISE), 420 tests/hour
(with ISE Na, K, Cl) - Optional: ISE module, Internal PC with touch screen, barcode reader
- High ergonomic design (special place for reagents screw
and reaction cover) - Cuvette washing system: 6-step wash station with washing solution
- 81 high light transmittance reaction cuvettes, optional quartz
glass cuvettes - Anti-contamination design (automatic probe and mixer washing,
intelligent anti-contamination program, carry-over contamination
rate ≤ 0.005%) - Anti-noise design (silent water cooling, operating noise < 65dB)
- Sample and Reagent tray – 40 positions for reagent, 40 positions
for sample with STAT priority - Refrigerated sample/reagent compartment 4-10°C
- Hot air thermostat for reaction cuvette
- Minimum reaction volume - 150 μl
- Longest reaction time – 15 min (single reagent); 12 min (double reagents)
- Test method -Endpoint, Two-point, Kinetic, Colorimetric,Turbidimetric
- Cal method - Linear (single-point, two- and multi-point), Logit-4P,
Logit-5P, spline, exponential, polynominal - Wavelengths (nm) - 340, 405, 450, 510, 546, 578, 630, 670, optional 800
- Halogen-tungsten lamp with > 2000h life time
- Overall water consumption : < 6,5 l/hour;
- User friendly software (multi-language; easy operating with iconic
interface; powerful statistic system; manual dilution; auto dilution
and post dilution; easy rerun and restore test) - Calibration and QC (Multiple calibration module, Advanced algorithm to obtain
best calibration curve; Multi QC rules: Westgard, Cumulative sum check, Twin plot) - Real Time Monitoring (reaction, calibration and QC test curve; sample, reagent
and reaction cuvette status; lamp intensity, distilled water and waste tank;
reaction and reagent disk temperature).
BM 500
- Throughput – up to 400 tests/hour (560 with ISE)
- ISE module for Na, K, Cl as option
- Build-in barcode reader for samples and reagents
- Reaction cuvettes – reusable 100 reaction cuvettes
- 8 steps cuvettes washing system
- Wavelengths – 12 wavelengths in the range 340 to 800 nm
- Two arm for mixing of sample and reagents
- Sample probe - with liquid level detection and collision protection
- and clot detector
- The volume of dispensed sample - 2-45 μl
- Up to 4 reagents in one reaction
- The volume of reagent dispensed - R1, R3 - 150-350 μl,
- R2, R4 - 20-250 μl
- Positions for reagents – 80 bottles 20, 30 ml and 70 ml,
- cooled to 2-10°C
- Positions for samples – 100 tubes with diameter 12 - 14 mm
- height 35-100 mm, microcups
- Connection to LIS – HL7 protocol
BM 100
- Throughput – up to 150 tests/hour (560 with ISE)
- Build-in barcode reader for samples and reagents
- Reaction cuvettes – reusable 81 reaction cuvettes
- Wavelengths – 8 wavelengths in the range 340 to 670 or 800 nm
- Additional arm for mixing of sample and reagents
- Sample probe - with liquid level detection and collision protection
- and clot detector
- The volume of dispensed sample - 2-30 μl
- The volume of reagent dispensed - R1: 150–300 μl; - R2: 20–300 μl
- Reaction volume - 150 - 500 μl
- Positions for reagents – 40 bottles 20, 30 ml, cooled to 4-10°C
- Positions for samples – 40 tubes with diameter 12 - 14 mm, height 35-100 mm, microcups
- Water consumption 1,5 L / hour.